Verify XProtect Transact configuration

When you are done configuring XProtect Transact and its components, you can test that Transact works as expected in XProtect Smart Client.

  1. Verify that the all required transaction sources have been added correctly in Management Client:
    1. Open XProtect Smart Client and click the Transact tab.
    2. Click the All sources drop-down menu and verify that all the transaction sources appear.
  2. Verify that the transaction definitions have been configured correctly in Management Client. If configured correctly, there is one receipt per transaction, and the lines break correctly:
    1. Open XProtect Smart Client and click the Transact tab.
    2. Select a transaction source that you know is active and click . The transaction lines for today appear.
    3. Click a line to view the associated receipt and video recordings.
  3. Verify that transaction events are configured correctly:
    1. Define a transaction test event in Management Client, for example an item that is likely to be purchased and registered on a connected transaction source, for example a cash register.
    2. When the event has occurred, open XProtect Smart Client and click the Alarm Manager tab.
    3. Open the alarm list and select Event. The most recent events are displayed at the top of the list. The test event you created should appear in the list.